DEHNventil M TT 2P (FM)

DA-951110

Modular combined lightning current and surge arrester for single-phase TT and TN-S systems with a nominal voltage of 230 V (1+1 configuration); FM version with floating remote signalling contact.

Categories: ,

Description

Technical data

SPD according to EN 61643-11 / IEC 61643-11 type 1 + type 2 / class I + class II
Energy coordination with terminal equipment (≤ 10 m) type 1 + type 2 + type 3
Nominal voltage (a.c.) (UN ) 230 V (50 / 60 Hz)
Max. continuous operating voltage (a.c.) [L-N] (UC ) 264 V (50 / 60 Hz)
Max. continuous operating voltage (a.c.) [N-PE] (UC (N-PE) ) 255 V (50 / 60 Hz)
Lightning impulse current (10/350 µs) [L+N-PE] (Itotal ) 50 kA
Specific energy [L+N-PE] (W/R) 625.00 kJ/ohms
Lightning impulse current (10/350 µs) [L-N]/[N-PE] (Iimp ) 25 / 50 kA
Specific energy [L-N]/[N-PE] (W/R) 156.25 / 625.00 kJ/ohms
Nominal discharge current (8/20 µs) [L-N]/[N-PE] (In ) 25 / 50 kA
Voltage protection level [L-N]/[N-PE] (UP ) ≤ 1.5 / ≤ 1.5 kV
Follow current extinguishing capability [L-N]/[N-PE] (Ifi ) 50 kArms / 100 Arms
Follow current limitation / Selectivity no tripping of a 20 A gG fuse up to 50 kArms (prosp.)
Response time (tA ) ≤ 100 ns
Max. backup fuse (L) up to I= 50 kArms 315 A gG
Max. backup fuse (L-L’) 125 A gG
Temporary overvoltage (TOV) [L-N] (UT) – Characteristic 440 V / 120 min. – withstand
Temporary overvoltage (TOV) [N-PE] (UT) – Characteristic 1200 V / 200 ms – withstand
Operating temperature range [parallel] / [series] (TU ) -40 °C … +80 °C / -40 °C … +60 °C
Operating state / fault indication green / red
Number of ports 1
Cross-sectional area (L, L’, N, N’, PE, 9) (min.) 10 mmsolid / flexible
Cross-sectional area (L, N, PE) (max.) 50 mmstranded / 35 mmflexible
Cross-sectional area (L’, N’, 9) (max.) 35 mmstranded / 25 mmflexible
For mounting on 35 mm DIN rails acc. to EN 60715
Enclosure material thermoplastic, red, UL 94-V-0
Place of installation indoor installation
Degree of protection IP 20
Capacity 4 module(s), DIN 43880
Approvals KEMA, VDE, UL
Extended technical data: Use in switchgear installations with prospective short-circuit currents of more than 50 kArms
– Max. prospective short-circuit current 100 kArms (220 kApeak)
– Limiting/cancelling of mains follow currents up to 100 kArms (220 kApeak)
– Max. backup fuse (L) up to IK = 100 kArms 315 A gG
Supplementary data: ———————————
– Voltage protection level [L-PE] (UP ) 2.2 kV
Use for 16.7 Hz traction power supply systems
– Nominal voltage (a.c.) (UN ) 230 V
– Nominal frequency (a.c.) (fN ) 16.7 Hz
– Max. backup fuse 125 A gG @ 16,7 Hz